Attic floor is defined as length x width floor of the attic.
Attic ventilation requirements irc.
Federal housing authority recommends a minimum of at least 1 square foot of attic ventilation evenly split between intake and exhaust for every 300 square feet of attic floor space.
Enclosed attics and enclosed rafter spaces formed where ceilings are applied directly to the underside of roof rafters shall have cross ventilation for each separate space by ventilating openings protected against the entrance of rain or snow.
For large volume attics such as where roof slopes.
Ventilation openings shall have a least dimension of 1 16 inch 1 6 mm minimum and 1 4 inch 6 4 mm maximum.
The amount of ventilation can be reduced to 1 300 in effect 50 less but 2 conditions must be met effective 1 1 18.
2015 international residential code for attic ventilation air vent inc.
Between half and two thirds of the provided ventilation shall be installed at the eaves.
Also when using a vapor retarder in an attic space irc 2012 limits the net free ventilation reduction from 1 150 to 1 300 for buildings in climate zones 6 7 and 8.
Always have a balanced ventilation system.
The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures.
The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.
More ventilation at the soffitsthan at the ridge will allow the attic to be slightly pressurized irc 2012 requirements reflect this approach for best results provide 50 to 75 of ventilation space at the soffits 60 40 is the optimal split.
In no case should the amount of exhaust ventilation exceed the amount of intake ventilation.
The ventilation openings shall have a least dimension of 1 16 inch 1 6 mm minimum and 1 4 inch 6 4 mm maximum.
The following are the requirements taken directly from the irc.
Enclosed attics and enclosed rafter spaces formed where ceilings are applied directly to the underside of roof rafters shall have cross ventilation for each separate space by ventilating openings protected against the entrance of rain or snow.
Let owens corning roofing help you calculate exactly how much ventilation you will need for a healthy and balanced attic with our 4 step ventilation calculator.
Air vent provides a complete line of ventilation products that meet the highest standards for quality and performance.