Attic area including eave soffit 104 x 124.
Attic ventilation formula.
To achieve a balanced system half that amount is intake and the other half is exhaust so each should be 3 3 square feet or 475 square inches.
Federal housing authority recommends a minimum of at least 1 square foot of attic ventilation evenly split between intake and exhaust for every 300 square feet of attic floor space.
It states that for every 150 sq.
If your roof is 1200 sq ft soffit floor space you will need 4 sq feet of roof ventilation.
30 feet x 50 feet 1 500 square feet.
Tips for assessing your needs.
There should also be a 50 50 balance of attic venting and roof venting.
Attic square footage 2 square inches of exhaust and square inches of intake net free area nfa needed.
Let owens corning roofing help you calculate exactly how much ventilation you will need for a healthy and balanced attic with our 4 step ventilation calculator.
Ok so now we know the square footage of the attic area to be ventilated.
According to the national roofing contractors association nrca a power vent with an airflow rate of 1 0 cubic foot per minute per square foot of attic space measured at the attic floor is generally considered to be equivalent to a 1 150 ventilation ratio.
Now let s figure out how much ventilation space we need.
Proper attic ventilation consists of a balance between air intake at your eaves soffits or fascias and air exhaust at or near your roof ridge.
Attic ventilation calculations made easy 84 24 3 7 2 212 768 56 x 84 56 x 39 3 2 2 120 0 3 8 5 3 3.
Calculation formula there is a generally agreed upon formula that you can apply for balanced attic ventilation known as the 1 150 rule.
Nfa is the unobstructed area through which air can pass through a vent usually measured in square inches.
Ventilation manufacturers assign an nfa value to the non motorized vents they make.
According to their requirements you should have 1 square foot of attic ventilation per 300 sq ft of attic floor space.
Remember the minimum area requirement when using a continuous system is a ratio of 1 300.
Calculate or enter the square footage of the attic or area to be vented.
The example below uses this exception and the calculation is based on a 100 x120 building with a hip roof and 2 overhangs on all sides.
Of attic space you need 1 sq.